Product
AC/DC 600A True RMS Clamp meter
600A DC/AC True RMS Industrial Clamp Meter
Specifications:
AC Current (accuracy: at the center of CT)
Range: 0 to 600.0A
Accuracy: ±(2.0%rdg+5dgts) on 20Hz to 100Hz
±(6.0%rdg+5dgts) on 100Hz to 400Hz
Resolution: 0.1A
AC Voltage
Range: 0 to 600.0V
Resolution: 0.1V
Accuracy: ±(1.0%rdg+5dgts) on 20 to 100Hz
±(6.0%rdg+5dgts) on 100 to 400Hz
Input impedance: 1MΩ
DC Current (accuracy: at the center of CT)
Range: 0 to 600.0A
Accuracy: ±(2.0%rdg+5dgts)
Resolution: 0.1A
DC Voltage
Range: 0 to 600.0V
Resolution: 0.1V
Accuracy: ±(1.0%rdg+5dgts)
Input impedance: 1MΩ
Resistance (Autorange)
Range: 0 to 999.9Ω, 1000 to 9999Ω
Accuracy: ±(1.5%rdg+5dgts)
Resolution: 0.1Ω/1Ω
Frequency
Range: 20 to 400.0Hz
Resolution: 0.1Hz
Sensitivity: 5Vrms TTL signal,
≥5A @20 to 100Hz, ≥10A @100 to 400Hz
Accuracy: ±(0.5%rdg + 5dgts)
Diode Test
Accuracy: ±(3.0%rdg+3dgts)
Resolution: 0.001V
Test current: 0.2mA
Test Voltage:
Continuity
Audible indication: less than 30Ω
Capacitance
Range: 0 to 999.9μF
Resolution: 0.1μF
Accuracy: ±(5.0%rdg + 10dgts)
Temperature (K-Type Thermocouple)
Range: -40°C to 1200°C, -40°F to 2200°F
Accuracy: ±(0.5%rdg+1°C)
±(0.5%rdg+2°F), (not including thermocouple error)
Resolution: 0.1°C on -40°C to 999.9°C
1°C on 1000°C to 1200°C
0.1°F on -40°F to 999.9°F
1°F on 1000°F to 2200°F
| Contact: | Stanley Hwang |
| Address: | 4F.-1 , No. 225, Sec. 3, Heping E. Rd., Sinyi District, Taipei, 11056, Taiwan (R.O.C.) |
| TEL: | 886-2-27375866 |
| FAX: | 886-2-27373343 |
| Email: |
sales@tecpel.com tecpelco@gmail.com |
| URL: | http://www.oka.com.tw http://www.tecpel.com |
| ZIP: | 11056 |